• Throughput: Up to 80 samples/hour
• Large capacity auto-loader (100 tubes)
• Stat sampling on open or closed tubes
• Automatic Sample Re-run
• Reagents: Only 5 onboard reagents and 1 diluent
• Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology
• 3 histograms for RBC, BAS/WBC and PLT
• High resolution 5 Diff Matrix include the determination of Atypical Lymphocytes (ALY**) and Large Immature Cells (LIC**)
• Basophils counted through specific channel
• High resolution reticulocyte Matrix for three stages of reticulocytes maturation quantification
• RHCc** Reticulocyte Hemoglobin Cellular content and reticulocytematuration parameters
• Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) - Fluorometry - DHSS* technology
• Integrated Workstation with Color Touch Screen
• Integrated Validation Station
• Customized Dilution Ratio (CDR)
• Micro-sampling from whole blood (CBC, RET: 35µl – Diff: 53µl)
* DHSS : Double Hydrodynamic Sequential System
** RUO parameters (Research Use Only)
Weight
138 lb / 62.5 kg
Power supply
100 V to 240 V (± 10%) - 50 Hz to 60 Hz
Dimensions
32.3 x 22.4 x 21.5 in / 82 cm x 57 cm x 54 cm
Printer
Laser
Throughput
Up to 80 samples/hour
Data Processing
Colour LCD touch screen: 12 in
PC onboard: Celeron 566 MHz
Windows XP Prof.
RAM (256 Mo), Hard disk (10 Go mini)
RS 232C, 5 USB
User defined flagging limits
Transmit patient files & QC to LIS
Uni-directional & bi-directional connections
ASTM protocol inside
Memory capacity
10 000 results + Graphics
Quality Control Management
36 selectable QC files
XB: 100 operator selectable files with statistics (20 results per file)
With-in run
Levey-Jennings graphs
Logs
Reagents, Quality Control, Calibration, Maintenance, Blank Cycle, Patients Data, Settings, Information, Technology Communication, Errors, by date.
Patient reports Management
Delta check
Anteriority (Matrix, curves, data)
Manual input
Parameters (36)
WBC, NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, ALY# & ALY%*, LIC# & LIC%*, RBC, HGB, HCT, MCV, MCH, MCHC, RDW CV, RDW SD, PLT, MPV, PCT*, PDW*,RET%, RET #, RETH%*, RETM%*, RETL%*, CRC%, IRF%, MRV*, RHCc*
Graphs
2 High-definition matrix: LMNE and RET
PLT, RBC, WBC/BAS curves
Blood Volume
CBC mode: 35 µL
CBC + DIFF mode: 53 µL
RET mode: 35 µL
Stability
48 hours post-draw stability
Operating sample mode
Autoloader 10 racks (100 tubes) capacity
Sample mixing with end-over-end tube rotation
Closed or open STAT tube
Identification
Alphanumeric. Bar-code reader and internal bar-code scanner
* RUO parameters (Research Use Only)
Parameters
Precision (%CV)
Linearity Limits
Linearity Limits with CDR*
WBC
< 2.0
0-120 x 10³/µL
120-360 x 10³/µL
RBC
< 2.0
0-8 106/µL
0-8 X 10^6/µL
HGB
< 1.0
0-24 g/dl
0-24 g/dL
HCT
< 2.0
0-67%
0-67%
PLT (whole blood)
< 5.0
0-1900 x 10³/µL
1900-3800 x 10³/µL
PLT (PLT concentrate)
< 5.0
0-2800 x 10³/µL
2800-5600 x 10³/µL
RET%
< 12.0
0-42%
RET#2800-5600 x 10³/µL
<20
0-1.5
0-1.5
*CDR: Customised Dilution Ratio
Blood Controls & Calibrators
Reference
Description
2062207
ABX Difftrol - 2L
2 x 3 mL vial
2062203
ABX Difftrol - 2N
2 x 3 mL vial
2062208
ABX Difftrol - 2H
2 x 3 mL vial
2072201
ABX Minotrol Retic - 2LN
2 x 3 mL vial
2072202
ABX Minotrol Retic - 1L 1H
2 x 3 mL vial
Reference
Description
2032002
Minocal Calibrator
1x2 mL
N: normal level, H: high level, L: low level
Recommended by HORIBA